Complete Self-Test D-2.5 and check your answers.
- What workplace safety requirements must a plumber comply with while working?
- CSA Standards
- National Plumbing Code
- Manufacturer’s regulations
- OHS Regulation
 
- When a job-site tool needs maintaining and servicing, what source of information would a plumber refer to in order to find the proper procedures?
- Project specifications
- Manufacturer’s specifications
- Wholesaler’s recommendations
- OHS Regulation
 
- The NPC requires that all gravity drainage piping be graded at least 1:50 in the direction of flow. What gravity drainage piping section is an exception to this requirement?
- 3 in. branch
- 3 in. building drain
- 3 in. fixture drain
- 4 in. building drain
 
- How much distance from an obstruction should be maintained from a C/O for adequate use of drain cleaning equipment?
- 1 ft (300 mm)
- 2 ft (600 mm)
- 3 ft (900 mm)
- 4 ft (1,200 mm)
 
- When determining the location of a cleanout fitting serving above-grade drainage piping, why is it important to consider the process being performed on the floor below?
- Minimizes the damage caused to sensitive equipment in the event of a blockage
- Minimizes the noise generated by the drain-cleaning equipment during the cleaning process
- Eliminates the plumber having to work in occupied spaces during the cleaning process
- Reduces the disruption of the building processes due to the blockage
 
- During a typical DWV installation, how many tests are performed on the system?
- 2
- 3
- 4
- 5
 
- What factors usually determine the type of roof flashings used when installing a vent terminal?
- Snow loading
- Rainfall intensity
- Roof slope and cladding material
- Directional orientation
 
- When placing a sleeve through a concrete wall for the future installation of a DWV piping section, how much larger should the ID of the sleeve be compared to the OD of the DWV piping?
- 1 in. (25 mm)
- 2 in. (50 mm)
- 3 in. (75 mm)
- 4 in. (100 mm)
 
- When a fire-stopping material is said to be intumescent, what property does it have?
- Shrinks when cooled
- Expands when cooled
- Shrinks when heated
- Expands when heated
 
- What type of device is used to fire-stop plastic DWV penetrations when a relatively large annular space is present?
- Mortar mix
- Fire collar
- Intumescent caulking
- Fire flashing
 
- What is the most common test for DWV piping systems?
- Smoke test
- Ball test
- Air test
- Water test
 
- What must be checked when receiving hazardous products?
- Quantity
- Colour
- Labels
- Price
 
- What should be done with construction waste?
- Sort before disposal
- Label properly
- Reduce quantity
- Plan for recycling and reuse
 
Answer Key: Self-Test D-2.5 is on the next page.