Self-Test D-1.4 Acceptable Pipe Material Application
Complete Self-Test D-1.4 and check your answers.
For each question, select all answers that apply.
- According to the NPC, in what applications are copper and brass pipes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
- According to the NPC, in what applications are Type K and L hard temper copper tubes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
- According to the NPC, in what applications are polyolefin laboratory drainage pipes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
- According to the NPC, in what applications are lead waste pipes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
- According to the NPC, in what applications are cast iron drainage pipes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
- According to the NPC, in what applications are PVC DWV pipes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
- According to the NPC, in what applications are Type M hard temper copper tubes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
- According to the NPC, in what applications are ABS DWV pipes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
- According to the NPC, in what applications are PVC sewer pipes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
- According to the NPC, in what applications are seamless galvanized steel pipes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
- According to the NPC, in what applications are plastic sewer pipes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
- According to the NPC, in what applications are DWV copper tubes permitted?
- Above-ground drainage inside building, any type of construction
- Above-ground drainage inside building, combustible construction only
- Underground drainage under building
- Building sewer
- Above-ground venting inside building, any type of construction
- Above-ground venting inside building, combustible construction only
- Underground venting under building
 
Answer Key: Self-Test D-1.4 is on the next page.