Answer Key: Self-Test D-1.9

1. Drawing 2P-38 — Drainage

Table 1 Answers
Number Name Hydraulic Load (FU) Size
1 Stack acting as a wet vent 2.5 3 in.
2 Stack 6 3 in.
3 Sanitary building drain 6 4 in. (preferred)
4 Sump discharge 15.85 2 in.
5 Sanitary building drain 21.85 4 in. (preferred)
6 Trap arm — Fixture drain 3 2 in.
7 Stack acting as a wet vent 5.5 3 in.
8 Stack 9 3 in.
9 Fixture drain — Acting as a wet vent 2.5 2 in.
10 Branch 6 3 in.
11 Branch 15 3 in.
12 Sanitary building drain 36.85 4 in. (preferred)
13 Fixture drain — Acting as a wet vent 1 2 in.
14 Branch 6 3 in.
15 Fixture drain 1.5 1.5 in.
16 Trap arm — Fixture drain 3 3 in.
17 Branch 4.5 3 in.
18 Branch 10.5 3 in.
19 Branch 3.5 2 in.
20 Fixture drain — Acting as a wet vent 1.5 1.5 in.
21 Branch 14 3 in.
22 Fixture drain 1.5 1.5 in.
23 Fixture drain 1.5 1.5 in.
24 Branch 3 1.5 in.
25 Sanitary building drain 39.85 4 in. (preferred)

2. Drawing 2P-38 — Venting

Table 2 Answers
Letter Name Hydraulic Load (FU) Length Size
A Continuous vent 6 36 m 2 in.
B Individual and continuous vent N/A N/A 1.25 in.
C Branch vent 7.5 36 m 2 in.
D Continuous vent 3.5 18 m 1.5 in.
E Branch vent 11 36 m 2 in.
F Sump vent N/A  N/A 2 in.
G Branch vent 27 36 m 3 in.
H Island vent (air admittance valve) 1.5 N/A 1.25 in.
I Individual and continuous vent N/A N/A 1.25 in.
J Continuous vent 6 9 m 1.5 in.
K Branch vent 7.5 13 m 1.5 in.
L Stack vent 9 11 m 1.5 in.
M Stack vent 16.5 11 m 2 in.
N Stack vent  (Clause 2.5.8.4 (5)) 6 7 m 3 in.
O Vent header 49.5 38 m 3 in.

3. Drawing 2P-39 — Drainage

Table 3 Answers
Number Name Hydraulic Load (FU) Size
1 Trap arm — Fixture drain 1 1.25 in.
2 Stack acting as a wet vent 2.5 3 in.
3 Stack 6 3 in.
4 Fixture drain 1.5 1.5 in.
5 Branch 3 1.5 in.
6 Branch 4.5 2 in.
7 Stack 10.5 3 in.
8 Trap arm — Fixture drain 1.5 1.5 in.
9 Branch 4.5 2 in.
10 Branch 9 2.5 in.
11 Stack 19.5 3 in.
12 Sanitary building drain 19.5 4 in. Preferred
13 Trap arm — Fixture drain N/A 3 in.
14 Sanitary building drain 19.5 4 in. Preferred
15 Stack acting as a wet vent 1 2 in.
16 Stack 8 3 in.
17 Sanitary building drain 27.5 4 in.
18 Fixture drain acting as a wet vent 1 2 in.
19 Branch 5 3 in.
20 Sanitary building drain 32.5 4 in.

4. Drawing 2P-39 — Venting

Table 4 Answers
Letter Name Hydraulic Load (FU) Length Size
A Continuous vent 5 15 m 1.5 in.
B Individual vent N/A N/A 1.5 in.
C Stack vent 8 22 m 2 in.
D Stack vent 8 22 m 2 in.
E Stack vent 13 22 m 2 in.
F Circuit vent 9 9 m 1.5 in.
G Relief vent N/A N/A 1.25 in.
H Branch vent 9 15 m 1.5 in.
I Stack vent 22 22 m 2 in.
J Individual and continuous vent N/A N/A 1.25 in.
K Dual and continuous vent N/A N/A 1.25 in.
L Branch vent 4.5 5 m 1.25 in.
M Stack vent 26.5 22 m 2 in.
N Stack vent 19.5 3 m 3 in.
O Vent header 32.5 31 m 3 in.

5. Drawing 2P-40 — Drainage

Table 5 Answers
Number Name Hydraulic Load (FU) Size
1 Stack 16 3 in.
2 Stack 17 3 in.
3 Branch 30 4 in.
4 Branch 42 4 in.
5 Stack 59 4 in.
6 Stack (Offset) 59 4 in.
7 Branch 4 2 in.
8 Stack 63 4 in.
9 Stack acting as a wet vent 2.5 2 in.
10 Stack 8 3 in.
11 Stack (Offset) 8 3 in.
12 Fixture drain 0.5 1.25 in.
13 Stack 8.5 3 in.
14 Branch 8.5 3 in.
15 Vent stack acting as a fixture drain sized as a wet vent 1.59 3 in.
16 Stack 73.09 4 in.
17 Sanitary building drain 73.09 4 in.

6. Drawing 2P-40 — Venting

Table 6 Answers
Letter Name Hydraulic Load (FU) Length Size
A Vent stack 73.09 35 m 3 in.
B Individual and continuous vent N/A N/A 1.25 in.
C Branch vent 1.5 15 m 1.5 in.
D Branch vent 4.5 15 m 1.5 in.
E Vent stack 73.09 35 m 3 in.
F Individual vent N/A N/A 1.25 in.
G Relief vent N/A N/A 1.5 in.
H Branch vent 43 11 m 2 in.
I Circuit vent 42 2 m 1.5 in.
J Branch vent 43 11 m 2 in.
K Vent stack 73.09 35 m 3 in.
L Stack vent 8.5 10 m 1.5 in.
M Stack vent 73.09 3 m 2 in.
N Vent header 73.09 10 m 2 in.

7. Drawing 2P-41 —Drainage

Table 7 Answers
Number Name Hydraulic Load (FU) Size
1 Stack acting as a wet vent 5 3 in.
2 Stack acting as a wet vent 5 3 in.
3 Branch 6.5 3 in.
4 Stack 18 3 in.
5 Stack 35.27 3 in.
6 Fixture drain acting as a wet vent 1 2 in.
7 Branch 13 3 in.
8 Stack 58.27 4 in.
9 Branch 61 4 in.
10 Stack 131.27 4 in.
11 Branch 8 3 in.
12 Stack 147.77 4 in.
13 Sanitary building drain 154.27 4 in.
14 Stack 7 3 in.
15 Branch 8 3 in.
16 Branch 8.5 3 in.
17 Stack 56.92 4 in.
18 Sanitary building drain 211.19 4 in.

8. Drawing 2P-41 — Venting

Table 8 Answers
Letter Name Hydraulic Load (FU) Length Size
A Individual vent N/A N/A 1.5 in.
B Individual and continuous vent N/A N/A 1.25 in.
C Continuous vent 8 21 m 1.5 in.
D Branch vent 8.5 21 m 2 in.
E Branch vent 46.92 21 m 3 in.
F Continuous vent 3 18 m 1.5 in.
G Branch vent 49.92 21 m 3 in.
H Branch vent 2.5 13 m 1.5 in.
I Branch vent 52.42 21 m 3 in.
J Branch vent 58.92 21 m 3 in.
K Continuous vent 9.27 7 m 1.5 in.
L Branch vent 68.19 21 m 3 in.
M Stack vent 56.92 9 m 3 in.
N Continuous vent 8 14 m 1.5 in.
O Branch vent 16.5 14 m 1.5 in.
P Vent stack 147.77 26 m 3 in.
Q Vent stack 147.77 26 m 3 in.
R Fixture drain acting as an additional circuit vent sized as a wet vent N/A N/A 2 in.
S Vent stack 148.77 26 m 3 in.
T Circuit vent 73 1 m 2 in.
U Individual and continuous vent acting as a relief vent N/A N/A 1.5 in.
V Branch vent 14 5 m 1.5 in.
W Continuous vent 10 3 m 1.5 in.
X Branch vent 18 5 m 1.5 in.
Y Stack vent 147.77 3 m 2 in.
Z Stack vent 6.5 3 m 3 in.

9. Drawing 2P-42 — Drainage

Table 9 Answers
Number Name Hydraulic Load (FU) Size
1 Stack acting as a wet vent 2 3 in.
2 Stack 9 3 in.
3 Branch 2 1.5 in.
4 Branch 4 2 in.
5 Branch 6 2 in.
6 Branch 18 3 in.
7 Fixture drain acting as a wet vent 2.5 2 in.
8 Stack 31 3 in.
9 Branch 8 3 in.
10 Stack 39 3 in.
11 Stack acting as a wet vent 3.5 2 in.
12 Stack acting as a wet vent 4.44 3 in.
13 Branch 6.66 3 in.
14 Stack 12.66 3 in.
15 Branch 12.66 3 in.
16 Fixture drain acting as a wet vent 2.5 2 in.
17 Branch — Wet vent 2.5 2 in.
18 Branch 16 3 in.
19 Stack 67.66 3 in.
20 Sanitary building drain 67.66 4 in.
21 Fixture drain 3 2 in.
22 Branch 18 3 in.
23 Sanitary building drain 85.66 4 in.

10. Drawing 2P-42 — Venting

Table 10 Answers
Letter Name Hydraulic Load (FU) Length Size
A Individual and continuous vent N/A N/A 1.5 in.
B Branch vent 9 12 m 1.5 in.
C Individual and continuous vent N/A N/A 1.5 in.
D Branch vent 18 12 m 1.5 in.
E Vent stack 67.66 18 m 2 in.
F Vent stack 85.66 18 m 2 in.
G Continuous vent 8 16 m 1.5 in.
H Continuous vent 8 14 m 1.5 in.
I Branch vent 16 16 m 2 in.
J Continuous vent 8 4 m 1.5 in.
K Branch vent 24 16 m 2 in.
L Dual and continuous vent N/A N/A 1.5 in.
M Branch vent 12 9 m 1.5 in.
N Branch vent 18 9 m 1.5 in.
O Vent stack 85.66 18 m 2 in.
P Stack vent 67.66 3 m 3 in.
Q Vent header 85.66 26 m 3 in.
R Continuous vent 4 3 m 1.25 in.
S Stack vent 12.66 2 m 1.5 in.
T Stack vent 6.66 2 m 1.5 in.

11. Drawing 2P-43 — Drainage

Table 11 Answers
Number Name Hydraulic Load (FU) Size
1 Stack 10 3 in.
2 Fixture drain acting as a wet vent 4 3 in.
3 Branch 12 3 in.
4 Stack 22 3 in.
5 Fixture drain acting as a circuit vent sized as a wet vent 1 2 in.
6 Stack 44 4 in.
7 Stack 51 4 in.
8 Branch 3 1.5 in.
9 Stack 54 4 in.
10 Branch — Wet vent 2.5 2 in.
11 Stack 60.5 4 in.
12 Sanitary building drain 60.5 4 in.
13 Stack acting as a wet vent 2.5 3 in.
14 Stack 6 3 in.
15 Fixture drain acting as a wet vent 1 1.5 in.
16 Branch 2.5 1.5 in.
17 Fixture drain acting as a wet vent 1 2 in.
18 Stack 32 4 in.
19 Branch 20 4 in.
20 Stack 68 4 in.
21 Branch 12 3 in.
22 Vent stack acting as a branch sized as a wet vent 2.59 3 in.
23 Stack 82.59 4 in.
24 Sanitary building drain 143.09 4 in.

12. Drawing 2P-43 — Venting

Table 12 Answers
Letter Name Hydraulic Load (FU) Length Size
A Circuit vent 12 8 m 1.5 in.
B Branch vent 12 8 m 1.5 in.
C Vent stack 82.59 33 m 3 in.
D Circuit vent 36 14 m 2 in.
E Relief vent N/A N/A 1.5 in.
F Branch vent 36 14 m 2 in.
G Continuous vent 6 8 m 1.5 in.
H Continuous vent 2.5 4 m 1.25 in.
I Individual vent N/A N/A 1.5 in.
J Branch vent 4.5 8 m 1.5 in.
K Stack vent 82.59 21 m 3 in.
L Vent header 82.59 40 m 3 in.
M Relief vent N/A N/A 1.5 in.
N Branch vent 13 14 m 1.5 in.
O Vent header 82.59 40 m 3 in.
P Continuous vent 6 4 m 1.5 in.
Q Vent stack 60.5 24 m 3 in.
R Vent stack 60.5 24 m 3 in.
S Dual and continuous vent N/A N/A 1.25 in.
T Continuous vent 7 2 m 1.5 in.
U Circuit vent 21 7 m 1.5 in.
V Branch vent 22 7 m 1.5 in.
W Continuous vent 5 2 m 1.5 in.
X Stack vent 60.5 9 m 3 in.
Y Vent header 60.5 25 m 3 in.
Z Vent header 143.09 40 m 3 in.

13. Drawing 2P-44 — Drainage

Table 13 Answers
Number Name Hydraulic Load (FU) Size
1 Branch 10 2.5 in.
2 Branch 9 3 in.
3 Stack 19 4 in.
4 Branch 8 2.5 in.
5 Branch 10 4 in.
6 Branch 34 4 in.
7 Branch 18 3 in.
8 Branch 32 4 in.
9 Stack acting as a wet vent 6 3 in.
10 Branch 7.5 3 in.
11 Branch 36 4 in.
12 Branch 108 4 in.
13 Branch 120 4 in.
14 Stack 242.5 5 in.
15 Sanitary building drain 242.5 5 in.
16 Trap arm — Fixture drain 2 2 in.
17 Branch 8 2.5 in.
18 Stack 69 4 in.
19 Stack acting as a wet vent 6 3 in.
20 Trap arm — Fixture drain 6 3 in.

14. Drawing 2P-44 — Venting

Table 14 Answers
Letter Name Hydraulic Load (FU) Length Size
A Vent stack 242.5 30 m 4 in.
B Circuit vent 120 21 m 3 in.
C Additional circuit vent N/A N/A 2 in.
D Branch vent 120 21 m 3 in.
E Branch vent 14 7 m 1.5 in.
F Vent stack 242.5 30 m 4 in.
G Circuit vent 30 13 m 2 in.
H Dual and continuous vent acting as a relief cent N/A N/A 1.5 in.
I Circuit vent 32 14 m 2 in.
J Branch vent 35 14 m 2 in.
K Vent stack 242.5 30 m 4 in.
L Continuous vent 7 8 m 1.5 in.
M Dual and continuous vent N/A N/A 1.5 in.
N Stack vent 242.5 5 m 3 in.
O Vent header 242.5 45 m 4 in.
P Branch vent 15 8 m 1.5 in.
Q Stack vent 7.5 7 m 3 in.
R Branch vent 19 12 m 1.5 in.

15. Drawing 2P-45 — Drainage

Table 15 Answers
Number Name Hydraulic Load (FU) Size
1 Stack 10 3 in.
2 Fixture drain acting as a wet vent 2.5 2 in.
3 Branch 6 3 in.
4 Stack 19 3 in.
5 Fixture drain acting as a wet vent 0.5 2 in.
6 Stack 23.5 3 in.
7 Stack 30.5 3 in.
8 Branch 8 2.5 in.
9 Stack 38.5 3 in.
10 Branch — Wet vent 1.5 2 in.
11 Stack 45.5 3 in.
12 Sanitary building drain 45.5 4 in.
13 Branch 85 4 in.
14 Sanitary building drain 130.5 4 in.
15 Stack acting as a wet vent 1 2 in.
16 Stack 5 3 in.
17 Stack 8 3 in.
18 Branch — Wet vent 2 1.5 in.
19 Branch 3.5 2 in.
20 Stack 11.5 3 in.
21 Fixture drain acting as a wet vent 1 2 in.
22 Stack 17.5 3 in.
23 Branch 20 4 in.
24 Stack 53.5 4 in.
25 Branch 12 3 in.
26 Vent stack acting as a fixture drain sized as a wet vent 1.5 3 in.
27 Stack 67 4 in.
28 Sanitary building drain 197.5 5 in.

16. Drawing 2P-45 — Venting

Table 16 Answers
Letter Name Hydraulic Load (FU) Length Size
A Circuit vent 12 8.5 m 1.5 in.
B Branch vent 12 8.5 m 1.5 in.
C Vent stack 67 42 m 3 in.
D Vent stack 67 42 m 3 in.
E Circuit vent 36 11 m 2 in.
F Relief vent N/A N/A 1.5 in.
G Branch vent 36 11 m 2 in.
H Vent stack 67 42 m 3 in.
I Continuous vent 6 9 m 1.5 in.
J Vent stack 67 42 m 3 in.
K Continuous vent 3.5 5.5 m 1.25 in.
L Vent stack 67 42 m 3 in.
M Individual vent N/A N/A 1.5 in.
N Branch vent 3 8.5 m 1.5 in.
O Vent stack 67 42 m 3 in.
P Stack vent 67 8 m 2 in.
Q Vent header 67 48.5 m 3 in.
R Continuous vent 5.5 3 m 1.5 in.
S Vent stack 45.5 30.2 m 3 in.
T Vent stack 45.5 30.2 m 3 in.
U Dual and continuous vent N/A N/A 1.5 in.
V Vent stack 45.5 30.2 m 3 in.
W Continuous vent 7 4 m 1.5 in.
X Vent stack 45.5 30.2 m 3 in.
Y Continuous vent 4.5 9 m 1.5 in.
Z Vent stack acting as a fixture sized as a wet vent 1.5 30.2 m 3 in.
AA Vent stack 45.5 30.2 m 3 in.
AB Continuous vent 6 5 m 1.5 in.
AC Vent stack 45.5 30.2 m 3 in.
AD Continuous vent 5 1 m 1.5 in.
AE Stack vent 45.5 5.7 m 1.5 in.
AF Continuous vent 5 1 m 1.5 in.
AG Stack vent 45.5 5.7 m 1.5 in.
AH Vent header 45.5 28.2 m 3 in.

License

Icon for the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License

Block D: Drainage Systems Copyright © 2025 by Skilled Trades BC, Thompson Rivers University is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License, except where otherwise noted.